UV-VIS SPECTROPHOTOMETER-108
Specifications |
4 Digit Display For %T, Abs & CONC;
Wave-Length Range: 200 to 700 nm with STD PMT and 200 to 900 with Special PMT;
Wave-Length Read out: 0.2 nm step;
Wave-Length Accuracy: + 0.5 nm;
Wave-Length Bandwidth: 0.5 nm;
Sample Holder: 4 position for 10 mm cuvette |
|
UV-VIS SPECTROPHOTOMETER-118
Specifications |
4 Digit Display For %T, Abs & CONC;
Wave-Length Range: 200 to 1000 nm;
Wave-Length Read out: 0.2 nm step;
Wave-Length Accuracy: + 1.01 nm;
Wave-Length Bandwidth: 2.0 nm;
Sample Holder: 4 position for 10 mm cuvette |
|
|
mP Based UV-VIS SPECTROPHOTOMETER - 117
m Processor based |
* 4 Line, 20 Character LCD Display for %T, ABS, CONCentration by K-Factor & Multi Standards;
* Operating Mode: Single W/L, Multi W/L, Spectrum Scan & Time Scan;
* Wave-Length Range: 200 to 1000 nm;
* Wave-Length Read out: 0.1 nm interval;
* Wave-Length Accuracy: + 1.0 nm;
* Wave-Length Band-Width: 2 nm;
* Sample Holder: 5 position holder for 10 mm cuvette;
* Printer Facility and Optional Data transfer to Computer through RS-232 (PC-Link) |
Specifications |
Display |
: 4 Line 20 Character LCD |
Operation Of the Instrument |
: Stand Alone (Data transfer to & manipulation of data by computer through RS 232) |
Operating Mode |
: %T, ABS, CONC by Factor & Multi Standard |
Measuring Mode |
: Single & Multi W/L, Spectrum & Time Scan |
Wave Length Range |
: 200 to 1000 nm |
Wave Length Accuracy |
: + 1 nm |
Wave Length Band Width |
: 2 nm |
Wavelength Read out |
: 0.1 nm |
Sample Holder |
: 5 Position (One position for reference) |
Detector |
: Photo Diode |
|
UV-VIS SPECTROPHOTOMETER - 119
Computer Operated
|
* Display of Graphical & Tubular data on PC Monitor;
* Measuring Mode: %T, ABS, CONCentration by K-Factor & Multi Standards;
* Operating Mode: Single W/L, Multi W/L, Spectrum Scan & Time Scan;
* Wave-Length Range: 200 to 1000 nm;
* Wave-Length Read out: 0.2 nm interval;
* Wave-Length Accuracy: + 1.0 nm;
* Wave-length Bandwidth: 2 nm;
* Sample Holder: 4 position holder for 10 mm cuvette;
* Printer Facility through PC
|
Specifications |
Display |
: Monitor of Computer; Graph & Data |
Operation Of the Instrument |
: Computer |
Operating Mode |
: %T, ABS, CONC by Factor & Multi Standard |
Measuring Mode |
: Single & Multi W/L, Spectrum & Time Scan |
Wave Length Range |
: 200 to 1000 nm |
Wave Length Accuracy |
: + 1 nm |
Wave Length Band Width |
: 2 nm |
Wavelength Read out |
: 0.2 nm |
Sample Holder |
: 4 Position |
Detector |
: Photo Diode |
|
|
Double Beam UV-VIS SPECTROPHOTOMETER - 2101
| Computer Operated |
* Display of Graphical & Tubular data on PC Monitor;
* Measuring Mode: %T, ABS, CONCentration by K-Factor & Multi Standards;
* Operating Mode: Single W/L, Multi W/L, Spectrum Scan & Time Scan;
* Wave-Length Range: 190 to 900 nm;
* Wave-Length Read out: 0.1 nm interval;
* Wave-Length Accuracy: + 0.5 nm;
* Wave-length Bandwidth: 0.5 to 6.0 nm;
* Sample Holder: 5 positions holder for 10 mm cuvette;
* Printer Facility through PC
|
| Specifications |
| Display |
: Monitor of Computer; Graph & Data |
| Operation Of the Instrument |
: Computer |
| Operating Mode |
: %T, ABS, CONC by Factor & Multi Standard |
| Measuring Mode |
: Single & Multi W/L, Spectrum & Time Scan |
| Wave Length Range |
: 190 to 900 nm |
| Wave Length Accuracy |
: + 0.5 nm |
| Wave Length Band Width |
: 0.5 to 6 nm Automatic with the incremental of 0.2 nm |
| Wavelength Read out |
: 0.1 nm |
| Sample Holder |
: 5 Position (One position for reference) |
| Detector |
: PMT |
|
|
|
|
 |
 |
 |
 |
|
|